R-Value Calculator

Add up the layers of a wall, roof or floor to get its total R-value, U-factor and heat flow through each square foot or metre.

Built by AbhiLast reviewed November 6, 2026

Units
Layers

Your energy details

Row 1
Row 2
Row 3

One row per layer, with the R-value from its label or data sheet.

Still air on each face adds a little resistance. Leave them out to match a product label.

Result

Total R-value: 14.9Estimate

US R units, along one path through the assembly

This is a thermal sum, not a purchase, so nothing is added.

Total RSI
2.62Estimate
U-factor, Btu/h·ft²·°F
0.067Estimate
U-value, W/m²·K
0.381Estimate
Heat flow, Btu/h per ft²
2.68Estimate
Heat flow, W per m²
8.47Estimate
Report a problem with this calculator
Your entries are kept on this device only.

Results are estimates based on the ratings, usage and prices you enter. Actual consumption, losses, tariffs and equipment performance vary. Check your bill, meter and manufacturer information before relying on the result. Read the full disclaimer

How to use the R-Value Calculator

  1. Choose whether your layer figures are US R-values or metric RSI.
  2. Add one row for each layer, using the value on its label or data sheet.
  3. Keep the surface films on for a full assembly, or leave them out to compare labels.
  4. Enter a temperature difference to see the heat flowing through each unit of area.

The sum

R total = layer 1 + layer 2 + … + inside film + outside filmU = 1 ÷ R totalHeat flow per area = temperature difference ÷ R total

Doubling R halves the heat flow, but the first few R matter most. Going from R-5 to R-10 saves far more heat than going from R-30 to R-35, which is why the heat flow row is useful alongside the total.

What the air films are

A thin layer of nearly still air clings to each face of a wall and adds a small resistance. Outside it is thinner because of wind. Tables give different values for walls, ceilings and floors, and this page uses the common values for a vertical wall.

Scope

This page describes one path through the layers. It does not model framing, thermal bridges, air leakage, moisture or wet insulation. Energy code targets vary by place, so check yours.

With your numbers

  1. Layers add in series, so heat crosses each in turn
  2. RSI = R × the metric factor = 2.62
  3. Heat flow = temperature difference ÷ RSI = 8.47 W per m²
  4. Total R = layers + surface films = 14.9

Quick reference

This is a thermal sum, not a purchase, so nothing is added.

Common energy examples, worked out with the options this calculator starts on for United States.
ExampleTotal R-value
R-13 wall with sheathing and drywall14.9
R-19 wall20.3
R-38 attic39.3
R-49 attic50.3
Labels only, no films14.05
RSI 2.5 wall15.5
RSI 6 loft35.37

Where the numbers come from

The fixed figures this calculator relies on, and the published source each one was checked against. How the calculators are built and checked

3 sources
  1. ASHRAE Handbook of Fundamentals, Heat, Air, and Moisture Control in Building Assemblies, surface resistances table, as cited at https://unmethours.com/answers/47567/revisions. Primary table not read; the founder should check it.

    Used for

    • Thermal resistance of the still-air film on the inside face of a vertical wall.
  2. ASHRAE Handbook of Fundamentals, surface resistances table, as cited at https://www.h2xengineering.com/blogs/air-film-resistance/. Primary table not read; the founder should check it.

    Used for

    • Thermal resistance of the outside air film at the 15 mph winter design wind.
  3. Derived from the exact foot, the Fahrenheit degree and the International Table Btu of 1055.05585262 J.

    Used for

    • One US R unit in metric RSI. Derived: 0.3048² × (5/9) × 3600 ÷ 1055.056.

Common questions about the R-Value Calculator

How do you add up R-values?
Add them. Heat passes through each layer in turn, so the resistances sum. An R-13 batt, sheathing at R-0.6 and drywall at R-0.45 make about R-14 before surface films.
What is the difference between R-value and U-factor?
R measures how well something resists heat, and U measures how much heat gets through. One is the reciprocal of the other, so an R-20 wall has a U-factor of 0.05.
Why is my whole wall worth less than this?
This adds one path through the layers. Studs are poorer insulators than the cavity beside them, so a real framed wall performs below the number for the insulated path.
How do I convert RSI to R?
One RSI is about 5.678 US R. A loft at RSI 6 is close to R-34.