CalcGallery

Heat Loss Calculator

Estimate the heat a room loses through its walls, ceiling, floor and windows and to air leakage, at one temperature difference.

Built by AbhiLast reviewed November 6, 2026

Units
Walls, area

Your energy details

In US R units. An RSI value × 5.678 gives the US R-value.

In US R units. An RSI value × 5.678 gives the US R-value.

In US R units. An RSI value × 5.678 gives the US R-value.

In US R units. An RSI value × 5.678 gives the US R-value.

How often leakage replaces the room’s air. A blower door test gives a real figure.

Result

Heat loss: 3,250 BTU/hEstimate

This is an estimate of heat, not a purchase, so nothing is added.

Through the surfaces
2,662 BTU/hEstimate
To air leakage
588 BTU/hEstimate
Report a problem with this calculator
Your entries are kept on this device only.

Results are estimates based on the ratings, usage and prices you enter. Actual consumption, losses, tariffs and equipment performance vary. Check your bill, meter and manufacturer information before relying on the result. Read the full disclaimer

How to use the Heat Loss Calculator

  1. Enter the area and R-value of the walls, ceiling, floor, and windows and doors.
  2. Enter the room volume and how many times an hour leakage replaces its air.
  3. Enter the difference between the inside and outside temperature you want to check.
  4. Change one surface at a time to see which improvement saves the most heat.

How the estimate is built

Surfaces = (A1 ÷ R1 + A2 ÷ R2 + …) × temperature differenceAir      = air heat capacity × volume × air changes per hour × temperature differenceHeat loss = surfaces + air

The result is a snapshot at one temperature difference. It tells you the rate of heat loss in that moment, not your yearly bill, and it scales directly with the difference you enter.

Finding the weak spot

Look at area divided by R for each surface: the biggest number is where most heat goes. Compare a change to walls with a change to windows using the page, because the cheapest improvement is often not the one with the highest R.

Scope

A steady-state estimate. It ignores heat stored in the building, sun, people, appliances, ground temperature below floors and ducts. Use R-values for the whole assembly where you can, since a layer figure can flatter a framed wall.

With your numbers

  1. Surfaces = each area ÷ its R × temperature difference = 2,662 BTU/h
  2. Air = air heat capacity × volume × air changes × temperature difference = 588 BTU/h
  3. Heat loss = both together = 3,250 BTU/h

Quick reference

This is an estimate of heat, not a purchase, so nothing is added.

Common energy examples, worked out with the options this calculator starts on for United States.
ExampleHeat loss
200 ft² room, 40 °F difference3,250 BTU/h
Same room at 60 °F difference4,876 BTU/h
Leaky room, 1 air change3,838 BTU/h
Better windows, R-42,850 BTU/h
Better walls, R-212,781 BTU/h
18.6 m² room, 22 K difference940 W

Where the numbers come from

The fixed figures this calculator relies on, and the published source each one was checked against. How the calculators are built and checked

3 sources
  1. Derived from the exact foot, the Fahrenheit degree and the International Table Btu of 1055.05585262 J.

    Used for

    • One US R unit in metric RSI. Derived: 0.3048² × (5/9) × 3600 ÷ 1055.056.
  2. U.S. Standard Atmosphere, 1976, NOAA-S/T 76-1562, NASA-TM-X-74335, Table I "Geometric Altitude, Metric Units", p. 53, Z = 0 m: T 288.150 K, P 1.01325E+3 mb, ρ 1.2250 kg/m³. https://ntrs.nasa.gov/citations/19770009539

    Used for

    • Density of air at sea level in the standard atmosphere, at 15 °C and 1013.25 hPa: 1.2250 kg/m³. Warmer, higher or more humid air is less dense.
  3. Moist-air enthalpy term of 1.006 kJ/kg·K, as in ASHRAE Handbook of Fundamentals, Psychrometrics. Primary chapter not read; the founder should check it.

    Used for

    • Specific heat of dry air near room temperature at constant pressure.

Common questions about the Heat Loss Calculator

How do you calculate heat loss for a room?
Divide each surface area by its R-value, add them up and multiply by the temperature difference. Then add the heat carried out by leaking air.
Can I size a furnace or heat pump from this?
No. Equipment sizing uses a full load calculation such as Manual J, which covers more than this page does. Use this to compare surfaces, and ask a qualified professional to size equipment.
Why do windows matter so much?
Their R-value is small. A 40 square foot window at R-2 can lose as much heat as about 260 square feet of R-13 wall.
What air change rate should I use?
A blower door test measures your own home. Without one the figure is a guess, so try a low and a high value to see how much it moves the answer.

Report a problem with this calculator